Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
ECT Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON or Engine Running Parameter Normal Range: -39 to 139°C (-38 to 282°F) |
|||
| Signal | 140°C (284°F) | -40°C (-40°F) | -40°C (-40°F)* |
| Low Reference | - | -40°C (-40°F) | -40°C (-40°F)* |
| *Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||
IAT Sensor 1
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON or Engine Running Parameter Normal Range: -39 to 129°C (-38 to +264°F) |
|||
| Signal | 130°C (266°F) | -40°C (-40°F) | -40°C (-40°F)* |
| Low Reference | - | -40°C (-40°F) | -40°C (-40°F)* |
| *Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||