LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2015 >> Cruze LT, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Engine Controls And Fuel - 2.0L (LUZ) Diesel - DTC P0016 To DTC P0406) >> Diagnostic Information and Procedures >> DTC P011B: Engine Coolant Temperature - Intake Air Temperature 1 >> Typical Scan Tool Data

Typical Scan Tool Data

WARNING: This page is about a different variant/trim than selected.
ECT Sensor

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON or Engine Running
Parameter Normal Range:  -39 to 139°C (-38 to 282°F)
Signal 140°C (284°F) -40°C (-40°F) -40°C (-40°F)*
Low Reference - -40°C (-40°F) -40°C (-40°F)*
*Internal ECM or sensor damage may occur if the circuit is shorted to B+.
IAT Sensor 1

Circuit Short to Ground Open Short to Voltage
Operating Conditions:  Ignition ON or Engine Running
Parameter Normal Range:  -39 to 129°C (-38 to +264°F)
Signal 130°C (266°F) -40°C (-40°F) -40°C (-40°F)*
Low Reference - -40°C (-40°F) -40°C (-40°F)*
*Internal ECM or sensor damage may occur if the circuit is shorted to B+.