Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
MAP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON Parameter Normal Range: 50-115 kPa (7.25-16.7 PSI) |
|||
| 5 V Reference | 20 kPa (2.9 PSI) 0.40 V |
20 kPa (2.9 PSI) 0.40 V |
253.7 kPa (36.8 PSI) 3.84 V |
| Signal | 0 kPa (0 PSI) 0.00 V |
300 kPa (43.5 PSI) 4.65 V |
300 kPa (43.5 PSI)* 4.65 V |
| Low Reference | - | 300 kPa (43.5 PSI) 4.65 V |
* |
| * Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||