Conditions for Running the DTCs
WARNING: This page is about a different variant/trim than selected.
P0096 and P0111
- DTCs P0097, P0098, P0112, P0113, P0117, P0118, P0119 or P1682 are not set.
- The vehicle has been OFF at least 8 hours.
- Ignition 1 voltage is at least 11 V for longer than 0.9 s.
- These DTCs run once per ignition cycle when the enabling conditions are met.