LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2015 >> Cruze LT, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 75 (Power Door Lock System And Release Systems) >> Diagnostic Information and Procedures >> DTC B3140, B3145, B3150, or B3155: Lock/Unlock Switch >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2015 Chevrolet Trax and 2015 Buick Encore. However, it is still accessible from the selected car via links, so may be relevant.

Driver Door Lock Switch Malfunction

  1. Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the S13D Door Lock Switch - Driver. It may take up to 2 minutes for all vehicle systems to power down.
  2. Test for less than 10 Ω between the ground circuit terminal 3 and ground.
    • If 10 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • If less than 10 Ω 
  3. Ignition ON.
  4. Verify the scan tool Driver Door Lock Switch parameter is Inactive.
    • If not Inactive 
    1. Ignition OFF, disconnect the harness connector at the K9 Body Control Module.
    2. Test for infinite resistance between the signal circuit terminal 4 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
    3. Test for infinite resistance between the signal circuit terminal 2 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K9 Body Control Module.
    • If Inactive 
  5. Install a 3 A fused jumper wire between the signal circuit terminal 4 and the ground circuit terminal 3.
  6. Verify the scan tool Driver Door Lock Switch parameter is Lock.
    • If not Lock 
    1. Ignition OFF, remove the 3 A fused jumper wire, disconnect the harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K9 Body Control Module.
    • If Lock 
  7. Install a 3 A fused jumper wire between the signal circuit terminal 2 and the ground circuit terminal 3.
  8. Verify the scan tool Driver Door Lock Switch parameter is Unlock.
    • If not Unlock 
    1. Ignition OFF, 3 A fused jumper wire, disconnect the harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K9 Body Control Module.
    • If Unlock 
  9. Test or replace the S13D Door Lock Switch - Driver.

Passenger Door Lock Switch Malfunction

  1. Ignition OFF and all vehicle systems OFF, disconnect the harness connector at the S13P Door Lock Switch - Passenger. It may take up to 2 minutes for all vehicle systems to power down.
  2. Test for less than 10 Ω between the ground circuit terminal 3 and ground.
    • If 10 Ω or greater 
    1. Ignition OFF.
    2. Test for less than 2 Ω in the ground circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, repair the open/high resistance in the ground connection.
    • If less than 10 Ω 
  3. Ignition ON.
  4. Verify the scan tool Passenger Door Lock Switch parameter is Inactive.
    • If not Inactive 
    1. Ignition OFF, disconnect the harness connector at the K9 Body Control Module.
    2. Test for infinite resistance between the signal circuit terminal 4 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
    3. Test for infinite resistance between the signal circuit terminal 2 and ground.
      • If less than infinite resistance, repair the short to ground on the circuit.
      • If infinite resistance, replace the K9 Body Control Module.
    • If Inactive 
  5. Install a 3 A fused jumper wire between the signal circuit terminal 4 and the ground circuit terminal 3.
  6. Verify the scan tool Passenger Door Lock Switch parameter is Lock.
    • If not Lock 
    1. Ignition OFF, 3 A fused jumper wire, disconnect the harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K9 Body Control Module.
    • If Lock 
  7. Install a 3 A fused jumper wire between the signal circuit terminal 2 and the ground circuit terminal 3.
  8. Verify the scan tool Passenger Door Lock Switch parameter is Unlock.
    • If not Unlock 
    1. Ignition OFF, 3 A fused jumper wire, disconnect the harness connector at the K9 Body Control Module, ignition ON.
    2. Test for less than 1 V between the signal circuit and ground.
      • If 1 V or greater, repair the short to voltage on the circuit.
      • If less than 1 V
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit.
      • If less than 2 Ω, replace the K9 Body Control Module.
    • If Unlock 
  9. Test or replace the S13P Door Lock Switch - Passenger.