Positive Crankcase Ventilation Pipe Removal

  1. Open the 2 positive crankcase ventilation pipe retainer clips (2) and (3).
    Fig 1: Positive Crankcase Ventilation Pipe Retainer Clips And Retainer Clamp
    GM2190425Courtesy of GENERAL MOTORS COMPANY
  2. Remove the positive crankcase ventilation pipe from the intake manifold.
    NOTE: Move retainer clamp (1) in direction of the arrow.
  3. Loosen the charger air bypass valve pipe clamp (4).
    Fig 2: Turbocharger, Positive Crankcase Ventilation Pipe Assembly And Charger Air Bypass Valve Pipe
    GM2190426Courtesy of GENERAL MOTORS COMPANY
  4. Remove the charger air bypass valve pipe from turbocharger.
  5. Remove the charger air bypass valve pipe (2) from turbo charger waste regulator solenoid valve.
  6. Disconnect the positive crankcase ventilation pipe from turbocharger (3).
  7. Unclip and remove the positive crankcase ventilation pipe assembly (1) from the camshaft cover retainer clips.