Removal Procedure
- Remove the air cleaner housing. Refer to Air Cleaner Assembly Replacement (1.8L LUW) and Air Cleaner Assembly Replacement (1.8L LWE) .
- Loosen the 3 water pump pulley bolts (1).
NOTE: Counterhold against crankshaft balancer bolt.
- Remove the drive belt. Refer to Drive Belt Replacement .
- Remove the 3 water pump pulley bolts (1).
- Remove the water pump pulley (2) from the water pump (3).