Diagnostic Fault Information
KR20C Cooling Fan Low Speed Relay
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Relay Coil Ignition | P0480, P0691 | 2 | - | - |
| Relay Switch B+ | 1 | 2 | - | - |
| Relay Coil Control | 3 | 2 | 4 | - |
| Relay Controlled Output | 1 | 2 | 3 | - |
|
||||
KR20D Cooling Fan High Speed Relay
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Relay Coil Ignition | P0480, P0691 | 2 | 1 | - |
| Relay Switch B+ | 2 | 2 | - | - |
| Relay Control | P0481 or P0693 | P0481 | P0481 or P0694 | - |
| Relay Controlled Output | 2 | 2 | 3 | - |
|
||||
KR20E Cooling Fan Speed Control Relay
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Relay Coil Ignition | P0480, P0691 | 1 | - | - |
| Relay Switch Ignition | P0480, P0691 | 1 | - | - |
| Relay Coil Control | 2 | 1 | 3 | - |
| Relay Controlled Output | 1 | 1 | 4 | - |
|
||||
KR20F Cooling Fan Relay
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Relay Coil Ignition | P0480, P0691 | P0480 | - | - |
| Relay Switch Ignition | 1 | 2 | - | - |
| Relay Control | P0480 or P0691 | P0480 | P0480 or P0692 | - |
| Relay Controlled Output | - | 2 | - | - |
|
||||
KR20P Cooling Fan Medium Speed Relay
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| Relay Coil Ignition | - | P0481 | - | - |
| Relay Switch B+ | 1 | 2 | - | - |
| Relay Control | P0481 or P0693 | P0481 | P0481 or P0694 | - |
| Relay Controlled Output | 1 | 2 | 3 | - |
|
||||