Component Testing
- Ignition OFF.
- Disconnect a KR20 Cooling Fan Relay.
- Test for 70-110 Ω between terminals 85/2 and 86/1. 95-135 Ω for the KR20F Cooling Fan Relay.
- If less than or greater than the specified range
Replace the KR20 Cooling Fan Relay.
- If within the specified range
- If less than or greater than the specified range
- Test for infinite resistance between the following terminals:
- 30/3 and 86/1
- 30/3 and 87/5
- 30/3 and 85/2
- 85/2 and 87/5
- If less than infinite resistance
Replace the KR20 Cooling Fan Relay.
- If infinite resistance
- Install a 20 A fused jumper wire between relay terminal 85/2 and 12 V.
- Install a jumper wire between relay terminal 86/1 and ground.
- Test for less than 2 Ω between terminals 30/3 and 87/5.
- If 2 Ω or greater
Replace the KR20 Cooling Fan Relay.
- If less than 2 Ω
- If 2 Ω or greater
- All OK.