Circuit/System Testing
- Ignition OFF, disconnect each KR20 cooling fan relay one at a time, in the order listed below, ignition ON:NOTE: The following tests must be performed on each cooling fan relay.
- KR20F Cooling Fan Relay
- KR20C Cooling Fan Low Speed Relay
- KR20P Cooling Fan Medium Speed Relay
- KR20D Cooling Fan High Speed Relay
- Verify that the cooling fan is not activated after each relay is removed.
- If the cooling fan is ON with all of the listed relays removed
- Ignition OFF, disconnect the harness connector at the G10 Cooling Fan Motor, ignition ON.
- Test for less than 1 V between ground and the relay controlled output circuit terminal listed below:
- KR20C Cooling Fan Low Speed Relay terminal 87/5
- KR20P Cooling Fan Medium Speed Relay terminal 30/3
- KR20D Cooling Fan High Speed Relay terminal 30/3
- If 1 V or greater, repair the short to voltage in the appropriate circuit.
- If the cooling fan is OFF after a listed relay is removed
- Replace the appropriate KR20 Cooling Fan Relay.