Diagnostic B
- Ignition OFF and all vehicle systems OFF, disconnect the KR76 Retained Accessory Power Relay. It may take up to 2 min for all vehicle systems to power down.
- Test for less than 10 Ω between the ground circuit terminal 13 and ground.
- If 10 Ω or greater
- Ignition OFF.
- Test for less than 2 Ω in the ground circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, repair the open/high resistance in the ground connection.
- If less than 10 Ω
- Ignition ON.
- Verify a test lamp illuminates between the B+ circuit terminal 15 and ground.
- If the test lamp does not illuminate
Replace the X51A Fuse Block - Instrument Panel
- If the test lamp illuminates
- If the test lamp does not illuminate
- Connect a test lamp between the control circuit terminal 11 and the ground circuit terminal 13.
- Verify the test lamp turns ON and OFF when commanding the Accessory/Retained Accessory Power relay On and Off with a scan tool.
- If the test lamp is always OFF
- Ignition OFF, remove the test lamp, disconnect the harness connector at the K9 Body Control Module.
- Test for infinite resistance between the control circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance
- Test for less than 2 Ω in the control circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the K9 Body Control Module.
- If the test lamp is always ON
- Ignition OFF, remove the test lamp, disconnect the harness connector at the K9 Body Control Module, ignition ON.
- Test for less than 1 V between the control circuit and ground.
- If 1 V or greater, repair the short to voltage on the circuit.
- If less than 1 V, replace the K9 Body Control Module.
- If the test lamp turns ON and OFF
- Verify that a test lamp does not illuminate between the ignition circuit terminal 14 and ground.
- If the test lamp illuminates
Repair the short to voltage on the ignition circuit
- If the test lamp does not illuminate
- If the test lamp illuminates
- Ignition ON, connect a 40 A fused jumper wire between the B+ circuit terminal 15 and the ignition circuit terminal 14.
- Verify device is activated.
- If the device does not activate
- Ignition OFF, disconnect the harness connector at the device.
- Test for infinite resistance between the ignition circuit and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance
- Test for less than 2 Ω in the ignition circuit end to end.
- If 2 Ω or greater, repair the open/high resistance in the circuit.
- If less than 2 Ω, replace the device.
- If the device activates
- Test or replace the KR76 Retained Accessory Power Relay.