LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2015 >> Cruze LT, Automatic Trans >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Wiring Systems And Power Management - Diagnostic Information And Procedures >> Diagnostic Information and Procedures >> Delphi Connectors (Push To Seat) >> Terminal Insertion Procedure

Terminal Insertion Procedure

  1. In order to reuse a terminal or lead assembly, refer to Wiring Repairs .
  2. Ensure that the cable seal is kept on the terminal side of the splice.
  3. Insert the lead from the back until it catches.
  4. Install the TPA, CPA and/or the secondary locks.