Component Testing
WARNING: This page is about a different variant/trim than selected.
Static Test
- Ignition OFF, disconnect the harness connector at the Q43 Valve Lifter Oil Manifold Assembly.
- Connect the harness that is labeled resistance from the Displacement On Demand (DOD) Tester to the Q43 Valve Lifter Oil Manifold Assembly connector.
- Connect the power leads from the DOD tester to B+ and ground. Test for 11-18 Ω on each cylinder deactivation solenoid valve.
- If not between 11-18 Ω
Replace the Q43 Valve Lifter Oil Manifold Assembly.
- If between 11-18 Ω
- If not between 11-18 Ω
- Test for infinite resistance between each valve lifter oil manifold circuit terminal and the valve lifter oil manifold housing.
- If less than infinite resistance
Replace the Q43 Valve Lifter Oil Manifold Assembly.
- If infinite resistance
- If less than infinite resistance
- Preform the Dynamic Test.
Dynamic Test
- Ignition OFF, disconnect the harness connector at the Q43 Valve Lifter Oil Manifold Assembly.
- Connect the cable that is labeled power from the Displacement On Demand (DOD) Tester to the connector.
- Connect the power leads from the DOD tester to B+ and ground.
- Command each cylinder deactivation solenoid valve ON and OFF using the DOD tester. You should be able to hear each solenoid turn ON and OFF.
- If the function does not perform as specified
Replace the Q43 Valve Lifter Oil Manifold Assembly.
- If the function performs as specified
- If the function does not perform as specified
- All OK.