Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
- Ignition ON, command the Cylinder Deactivation System ON and OFF with a scan tool:
- Verify the follow parameters display OK or Not Run during each command.
- Cylinder 1, 4, 6, or 7 Deactivation Solenoid Valve Control Circuit High Voltage Test Status
- Cylinder 1, 4, 6, or 7 Deactivation Solenoid Valve Control Circuit Open Test Status
- Cylinder 1, 4, 6, or 7 Deactivation Solenoid Valve Control Circuit Low Voltage Test Status
- If any parameter displays Malfunction
Refer to Circuit/System Testing.
- If each parameter displays OK or Not Run
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
- Verify the DTC P3401, P3425, P3441, or P3449 does not set.
- If a DTC set
Refer to Circuit/System Testing.
- If a DTC does not set
- If a DTC set
- All OK.
NOTE:
DTC P3401, P3425, P3441, and P3449 set with an open ignition circuit fuse.