Component Testing
WARNING: This page is about a different variant/trim than selected.
NOTE:
You must perform the Circuit/System Testing before proceeding with the Component Test.
- Ignition Off, remove the B17 Barometric Pressure sensor.
- Install a 3 A fused jumper between the harness connector 5 V reference circuit terminal 1 and terminal 1 of the sensor.
- Install a jumper wire between the low reference terminal 2 of the sensor and ground
- Connect a DMM between terminal 3 of the sensor and ground.
- Ignition On, slowly apply vacuum to the sensor with the GE 23738-A .
- Verify the voltage is between 0.2-4.9 V and changes without any spikes or dropouts.
- If not between 0.2-4.9 V, does not change or has spikes or dropouts
Replace the B17 Barometric Pressure Sensor.
- If between 0.2-4.9 V, and changes without any spikes or dropouts
- If not between 0.2-4.9 V, does not change or has spikes or dropouts
- All OK.