Static Test
- Ignition OFF, disconnect the harness connector at the Q12 Evaporative Emission Purge Solenoid Valve.
- Test for 10-30 Ω between the control circuit terminal 2 or B and the ignition circuit terminal 1 or A.
- If not between 10-30 Ω
Replace the Q12 Evaporative Emission Purge Solenoid Valve.
- If between 10-30 Ω
- If not between 10-30 Ω
- All OK.
Dynamic Test
- Ignition OFF, disconnect the harness connector at the Q12 Evaporative Emission Purge Solenoid Valve.
- Install a 3 A fused jumper wire between the ignition terminal 1 or A and 12 V. Install a jumper wire between the control terminal B or 2 and ground.
- Verify the Evaporative Emission Purge Solenoid Valve turns on and off/clicks and flows vacuum.
- If it does not turn on and off/click or flow vacuum
Replace the Q12 Evaporative Emission Purge Solenoid Valve.
- If it does turn on and off/clicks and flows vacuum
- If it does not turn on and off/click or flow vacuum
- All OK.