Component Testing
- Ignition OFF, disconnect the harness connector at the B55 Hood Ajar Switch.
- Test for 2738-3350 Ω between the signal terminal 1 and the signal terminal 2 with the hood latch in the CLOSED position.
- If not between 2738-3350 Ω
Replace the B55 Hood Ajar Switch.
- If between 2738-3350 Ω
- If not between 2738-3350 Ω
- Test for 658-806 Ω between the signal terminal 2 and the ground terminal 3 with the hood latch in the CLOSED position.
- If not between 658-806 Ω
Replace the B55 Hood Ajar Switch.
- If between 658-806 Ω
- If not between 658-806 Ω
- Test for 2080-2545 Ω between the signal terminal 1 and the ground terminal 3 with the hood latch in the CLOSED position.
- If not between 2080-2545 Ω
Replace the B55 Hood Ajar Switch.
- If between 2080-2545 Ω
- If not between 2080-2545 Ω
- Test for 2738-3350 Ω between the signal terminal 1 and the signal terminal 2 with the hood latch in the OPEN position.
- If not between 2738-3350 Ω
Replace the B55 Hood Ajar Switch.
- If between 2738-3350 Ω
- If not between 2738-3350 Ω
- Test for 2080-2545 Ω between the signal terminal 2 and the ground terminal 3 with the hood latch in the OPEN position.
- If not between 2080-2545 Ω
Replace the B55 Hood Ajar Switch.
- If between 2080-2545 Ω
- If not between 2080-2545 Ω
- Test for 658-806 Ω between the signal terminal 1 and the ground terminal 3 with the hood latch in the OPEN position.
- If not between 658-806 Ω
Replace the B55 Hood Ajar Switch.
- If between 658-806 Ω
- If not between 658-806 Ω
- All OK.