Positive Crankcase Ventilation Valve Replacement (LTG)
Positive Crankcase Ventilation Valve Replacement (LTG)
| Callout | Component Name |
|---|---|
| Preliminary Procedures Remove the positive crankcase ventilation hose. Refer to Positive Crankcase Ventilation Hose/Pipe/Tube Replacement (Camshaft Cover to Air Cleaner Resonator to Outlet Duct)
NOTE:
Inspect each component while attached to the camshaft cover. Do not remove the PCV components unless inspection indicates a suspect component. Replace the PCV valve, PCV tube assembly, and PCV hose fitting as an assembly. The connections between these components are permanent. |
|
| 1 | Positive Crankcase Ventilation Valve Fastener
CAUTION:
Refer to Fastener Caution . Tighten 10 (89 lb in) |
| 2 | Positive Crankcase Ventilation Valve Procedure Inspect the PCV valve. If the PCV valve is suspect, use a suitable tool to pry the valve off of the cover. Retrieve any particles that fall onto the baffle in the cover. Discard the valve and particles.
NOTE:
When the PCV valve is removed, small particles of the valve will break and fall into the cover. |
| 3 | Positive Crankcase Ventilation Valve |