Component Testing
- Ignition OFF, disconnect the harness connectors at the fuel level sensor.
- Sweep the fuel level sensor through its full range of motion while measuring resistance between the signal terminal and the low reference terminal listed below:
- Signal Terminal C (5.3L)
- Low Reference Terminal B (5.3L)
- Signal terminal B (4.3L, 4.8L or 6.0L)
- Low Reference Terminal C (4.3L, 4.8L or 6.0L)
- Signal Terminal B (6.6L Diesel)
- Low Reference Terminal C (6.6L Diesel)
- Test for a minimum resistance value of 37-43 Ω and a maximum value of 245-255 Ω without any spikes or dropouts.
- If minimum resistance is not 37-43 Ω, maximum resistance is not 245-255 Ω or if there are any spikes or dropouts
Replace the fuel level sensor.
- If minimum resistance is 37-43 Ω, maximum resistance is 245-255 Ω and if there are no spikes or dropouts
- If minimum resistance is not 37-43 Ω, maximum resistance is not 245-255 Ω or if there are any spikes or dropouts
- All OK.