Circuit/System Verification
- Ignition ON, observe the scan tool ECM - Fuel Level Sensor parameters. The reading should be between 0.5-3.5 V and vary with fuel level.
- Ignition ON, perform the Instrument Cluster Gauge Sweep test with the scan tool, verify that the fuel level gauge sweeps from its low to high position.
- If the fuel level gauge does not sweep, replace the instrument cluster.