Circuit/System Testing
- Ignition ON, verify that the instrument panel cluster warning indicators are illuminated.
- If the instrument panel cluster warning indicators are not illuminated, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, replace the P16 instrument panel cluster.
- Ignition OFF, disconnect ECM X1 harness connector. Ignition ON, the Wait to Start Lamp should not illuminate.
- If the Wait to Start Lamp is illuminated, test the Wait To Start Indicator Control circuit terminal X1 20 for a short to ground. If the circuit tests normal, replace the P16 instrument panel cluster.
- Ignition ON, connect a 3 A fused jumper wire between the Wait To Start Indicator Control circuit terminal X1 20 and ground. The Wait to Start Lamp should illuminate.
- If the Wait to Start Lamp does not illuminate, test the Wait to Start Indicator Control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the P16 instrument panel cluster/bulb.
- If all circuits/connections test normal, replace the K20 engine control module.