Home >> Chevrolet >> 2013 >> Trax LS, Standard Trans >> Repair and Diagnosis (Single Page) >> Quick Lookups >> Wiring Diagrams >> Wiring Systems And Power Management - Inline Harness Connector End Views - X302 To X904 >> Inline Harness Connector End Views >> X331 Body Harness To Headliner Harness

X331 Body Harness To Headliner Harness

GM2173982
GM2220413
Connector Part Information
  • Harness Type: Headliner
  • OEM Connector: 1897543-2
  • Service Connector: 13395404
  • Description: 22-Way F MQS/MCP 2.8 Series (BK)
Connector Part Information
  • Harness Type: Body
  • OEM Connector: 1897540-2
  • Service Connector: 13580994
  • Description: 22-Way M MQS/MCP 2.8 Series (BK)
Terminal Part Information

Terminal Type ID Terminated Lead Diagnostic Test Probe Terminal Removal Tool Service Terminal Tray Core Crimp Insulation Crimp
I Pending Pending Pending Pending Pending Pending Pending
X331 Body Harness To Headliner Harness

Pin Size Color Circuit Terminal Type ID Option Function Pin Size Color Circuit Terminal Type ID Option
1 0.35 BK/BU 7566 I (CJ2UFL-CE1)/(CJ2-UFL) Humidity/Windscreen Temp Sensor Low Reference 1 0.35 BK/BU 7566 I CJ2
2 0.35 YE/RD 597 I (CJ2UFL-CE1)/(CJ2-UFL) 5 Volt Reference 2 0.35 YE/RD 597 I CJ2
3 0.35 GY/GN 7565 I (CJ2UFL-CE1)/(CJ2-UFL) Windscreen Temp Sensor Signal 3 0.35 GY/GN 7565 I CJ2
4 0.35 GY/BU 7564 I (CJ2UFL-CE1)/(CJ2-UFL) Humidity Sensor Signal 4 0.35 GY/BU 7564 I CJ2
5 0.35 YE/BU 3197 I (CJ2UFL-CE1)/(CJ2-UFL) Humidity Temperature Sensor Signal 5 0.35 YE/BU 3197 I CJ2
6 0.35 GY/WH 3272 I (-CF5) Remote Function Actuator Supply Voltage 6 0.35 GY/WH 3272 I -UFL
7 0.35 YE/GN 3274 I (-CF5) Remote Function Actuator Transmit Signal 7 0.35 YE/GN 3274 I -UFL
8 0.35 BU/WH 3275 I (-CF5) Remote Function Actuator Receive Signal 8 0.35 BU/WH 3275 I -UFL
9 0.5 RD/YE 1142 I UFL Battery Positive Voltage 9 0.5 RD/YE 1142 I STD
10 0.35
0.35
RD/GN
RD/GN
1840
1840
I CE1-UFL
CE1UFL
Battery Positive Voltage
Battery Positive Voltage
10 0.35 RD/GN 1840 I STD
11 - - - - - Not Occupied 11 - - - - -
12 0.75 YE 200 I STD Right Front Speaker (+) (1) 12 0.75 YE 200 I STD
13 0.75 YE/BK 117 I STD Right Front Speaker Signal (-) (1) 13 0.75 YE/BK 117 I STD
14 0.35 GY 3273 I (-CF5) Remote Function Actuator Return 14 0.35 GY 3273 I -UFL
15 0.5 GN 5060 I UFL Low Speed GMLAN Serial Data 15 0.35 GN 5060 I STD
16 0.35 WH 3152 I UFL Lane Departure Warning Indicator Control 16 0.35 WH 3152 I UFL
17 0.35 GY/WH 3153 I UFL Lane Departure Warning Disable Switch Signal 17 0.35 GY/WH 3153 I UFL
18 0.75 BK/WH 1451 I STD Signal Ground 18 0.75 BK/WH 1451 I STD
19 - - - - - Not Occupied 19 - - - - -
20 0.35 BK/BN 654 I (UNM/UE1) Cellular Telephone Microphone Low Reference 20 0.35 BK/BN 654 I STD
21 0.35 BU 655 I (UNM/UE1) Cellular Telephone Microphone Signal 21 0.35 BU 655 I STD
22 - - - - - Not Occupied 22 - - - - -