Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
BARO
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Ignition ON, Engine OFF Parameter Normal Range: 56-105 kPa (8.1-15.2 psi), varies with altitude |
|||
| 5 V Reference | 0 kPa (0 psi) | 0 kPa (0 psi) | 127 kPa (18.4 psi) |
| Signal | 0 kPa (0 psi) | 0 kPa (0 psi) | 127 kPa (18.4 psi) |
| Low Reference | - | 127 kPa (18.4 psi) | - |