Conditions for Setting the DTC
P0776 - Condition 1
The clutch pressure control solenoid 2 commanded pressure is 1800 kPa (261 psi) and the transmission fluid pressure switch 3 state is Low for 30 seconds.
P0776 - Condition 2
The clutch pressure control solenoid 2 commanded pressure is 1800 kPa (261 psi) and the transmission fluid pressure switch 3 state is Low for 0.5 seconds greater than 5 times during a key cycle.
P0777 - Condition 1
The clutch pressure control solenoid 2 commanded pressure is 5 kPa (1 psi) and the transmission fluid pressure switch 3 state is High for 36 seconds.
P0777 - Condition 2
The clutch pressure control solenoid 2 commanded pressure is 5 kPa (1 psi) and the transmission fluid pressure switch 3 state is High for 1.25 seconds greater than 5 times during a key cycle.