Conditions for Setting the DTC
WARNING: This page is about a different car, the 2012 GMC Yukon, 2012 Chevrolet Tahoe, and 2012 Cadillac Escalade. However, it is still accessible from the selected car via links, so may be relevant.
P0711
- The difference between the TCM temperature and Trans. Fluid Temp. is greater than 15-50°C (59-122°F), depending on the highest of the Trans. Fluid Temp., TCM temperature and TCM power up temperatures.
- The difference between the TCM power up temperature and TCM substrate temperature is greater than 15-50°C (59-122°F), depending on the highest of the Trans. Fluid Temp., TCM temperature and TCM power up temperatures.
- The above conditions have to be met for 5 minutes.
P0712
The Trans. Fluid Temp. parameter is less than -60°C for greater than 60 seconds.
P0713
The Trans. Fluid Temp. parameter is greater than 160°C for less than or equal to -60°C (-76°F) for greater than 60 seconds.