Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the B9 Ambient Air Temperature Sensor.
- Ignition ON, test for 4.8-5.2 V between the signal circuit terminal 1 and ground.
- If greater than the specified range, test the signal circuit terminal 1 for a short to voltage. If the circuit tests normal, replace the P16 Instrument Cluster.
- If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the P16 Instrument Cluster.
- Install a 3 A fused jumper wire between the signal circuit terminal 1 and the low reference circuit terminal 2. Verify the scan tool Ambient Air Temperature Sensor parameter displays 0%.
- If greater than the specified value, test the low reference circuit a short to voltage or an open/high resistance. If the circuit tests normal, replace the P16 instrument cluster.
- If all circuits test normal, test or replace the B9 Ambient Air Temperature Sensor.