Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the B37 Engine Oil Pressure Switch.
- Ignition ON, verify the scan tool Engine Oil Pressure Switch parameter is OK.
- If not the specified value, test for the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the K20 Engine Control Module.
- Install a 3 A fused jumper wire between the signal circuit terminal 1 and ground. Verify the scan tool Engine Oil Pressure Switch parameter is Low.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K20 Engine Control Module.
- If all circuits test normal, test or replace the B37 Engine Oil Pressure Switch.