Diagnostic Aids
WARNING: This page is about a different variant/trim than selected.
- The EVAP system can be filled with smoke more quickly and completely by opening the system opposite the end where the smoke is injected. When injecting smoke at the service port tool temporarily leave the EVAP vent solenoid valve open until smoke is observed then close the system and continue testing.
- To help locate intermittent leaks using the GE 41413-A Evaporative Emissions System Tester (EEST), move all EVAP components while observing smoke with the GE 41413-SPT High Intensity White Light.
- Individual components can be isolated and tested using adapters in the GE 41413-300 EVAP Cap and Plug Kit.
- A condition may exist where a leak in the EVAP system only exists under a vacuum condition. This type of leak may be detected by using the scan tool Purge/Seal function to create a vacuum in the EVAP system and then observe the FTP parameter for vacuum decay.