Blower Motor Inoperative

WARNING: This page is about a different car, the 2010 Pontiac G5 and 2010 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the X3 harness connector at the HVAC control module.
  2. Ignition OFF, test for less than 1.0 ohm between the ground circuit terminal B and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition OFF, connect the X3 harness connector at the HVAC control module. Disconnect the X2 harness connector at the HVAC control module.
  4. Test for less than 1.0 ohm between the ground circuit terminal 9 and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  5. Ignition ON, verify a test lamp illuminates between the B+ circuit terminal 10 and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  6. Ignition OFF, connect the X2 harness connector at the HVAC control module. Disconnect the X1 harness connector at the HVAC control module.
  7. Ignition ON, verify a test lamp illuminates between the ignition circuit terminal 8 and ground.
    • If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.
  8. Ignition OFF, connect the X1 harness connector at the HVAC control module. Disconnect the HVAC relay.
  9. Verify that a test lamp illuminates between the B+ circuit terminal 30 and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  10. Ignition ON, verify a test lamp illuminates between the control circuit terminal 85 and the control circuit terminal 86.
    • If the test lamp does not illuminate, replace the BCM.
  11. Ignition OFF, connect the HVAC relay. Disconnect the harness connector at the blower motor.
  12. Ignition ON, verify a test lamp illuminates between the ignition circuit terminal B and ground.
    • If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the HVAC relay.
  13. Ignition OFF, blower switch HIGH, test for less than 5 ohms between the control circuit terminal A and ground.
    • If greater than the specified range, test the control circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
  14. If all circuits test normal, test or replace the blower motor.