Component Testing
WARNING: This page is about a different car, the 2010 Pontiac G5 and 2010 Chevrolet Cobalt. However, it is still accessible from the selected car via links, so may be relevant.
- Install a 10-amp fused jumper wire between the control terminal A and 12 volts. Momentarily install a jumper wire between the control terminal B and ground. The recirculation actuator shaft should rotate.
- If the function does not perform as specified, replace the recirculation actuator.
- Reverse the jumper wires; the recirculation actuator shaft should rotate.
- If the function does not perform as specified, replace the recirculation actuator.