Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Measure the resistance between the VSS high signal circuit and the VSS low signal circuit. The resistance should be between 1, 420-2, 140 ohms.
- If the value is greater than 2, 140 ohms, test the VSS high signal circuit and the VSS low signal circuit for an open.
- If the value is less than 1, 420 ohms, test the VSS high signal and the VSS low signal circuits for a shorted together condition.
- Measure the resistance of the VSS high signal circuit to ground. The resistance should be greater than 10M ohms.
- If the value is less than 10M ohms, repair the short to ground.
- Measure the resistance between the VSS low signal circuit and ground. The resistance should be greater than 10M ohms.
- If the value is less than 10M ohms, repair the short to ground.
- Reconnect the ECM connector. Disconnect the VSS connector. Ignition ON, test the VSS high signal circuit for a short to voltage.
- If all circuits/connections test normal, test or replace the VSS.
- If all previous steps for circuit checking and VSS replacement have been made and all component testing has been performed and the condition persists replace the ECM.