LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2011 >> Suburban C2500 >> Repair and Diagnosis >> External Pages >> Different car >> Section 1767 (Automatic Transmission - 2ML70 - Repair Instructions - Off Vehicle) >> Repair Instructions - Off Vehicle >> Torque Dampener Housing and Fluid Pump Cover Installation

Torque Dampener Housing and Fluid Pump Cover Installation

WARNING: This page is about a different car, the 2011 GMC Yukon, 2011 Chevrolet Tahoe, and 2011 Cadillac Escalade. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Torque Dampener Housing And Fluid Pump Cover Tightening Sequence
GM1867828Courtesy of GENERAL MOTORS CORP.
Torque Dampener Housing and Fluid Pump Cover Installation

Callout Component Name
1 A/Trans Torque Dampener Housing Gasket
TIP:  Do not reuse the gasket. Replace with a NEW gasket.
2 A/Trans Torque Dampener (w/Fluid Pump) Housing Assembly
3 A/Trans Fluid Pump Cover Bolt M8 x 1.25 x 25 (Qty: 12)
CAUTION:

Refer to Fastener Caution .


Procedure: 
Tighten in the sequence shown.
Tighten 
24-29 N.m (17.70-21.38 lb ft)