- Ignition OFF, using the remover J 44257 , disconnect the automatic transmission inline 20-way connector and install the jumper harness J 44152 on the transmission pass-thru connector. See Special Tools .
- Using the light-blue test probes J 35616-65B from the most current J 35616 GM terminal test kit, test for 820-1428 Ω between the ISS high signal circuit jumper harness pin S and the ISS low signal circuit jumper harness pin V.
- If greater than the specified range, test the affected circuits for an open/high resistance. If both circuits test normal, replace the ISS.
- If less than the specified range, test the affected circuits for a shorted together condition. If both circuits test normal, replace the ISS.
- Test for greater than 10K Ω between the ISS high signal circuit jumper harness pin S and all other circuits of the jumper harness J 44152
, except the ISS low signal circuit jumper harness pin V. See Special Tools
.
- If less than the specified range, the affected circuits are shorted together. Replace the transmission internal wire harness.
- Test for greater than 250 Ω from the ISS high signal circuit jumper harness pin S and the ISS low signal circuit jumper harness pin V to the transmission case.
- If less than the specified value, test the affected circuits for a short to the transmission case. If both circuits test normal, replace the ISS.
- Using the remover J 44257 , remove the jumper harness J 44152 from the transmission pass-thru connector and install it on the engine side of the AT inline 20-way connector. See Special Tools .
- Disconnect the X1 harness connector at the TCM.
- Using the light blue probes J 35616-64B, test for greater than 250 Ω from the ISS high signal circuit jumper harness terminal S and the ISS low signal circuit jumper harness terminal V to a good ground.
- If less than the specified value, test the affected circuit for a short to ground.
- Using the light blue probes J 35616-64B, test for greater than 10K Ω between the ISS high signal circuit jumper harness terminal S and all other circuits of the jumper harness J 44152
. See Special Tools
.
- If less than the specified value, the affected circuits are shorted together.
- Using the light blue probes J 35616-64B, test for greater than 10K Ω between the ISS low signal circuit jumper harness terminal V and all other circuits of the jumper harness J 44152
. See Special Tools
.
- If less than the specified value, the affected circuits are shorted together.
- Using the light blue probes J 35616-64B, test the ISS high signal circuit for less than 10 Ω between the jumper harness J 44152
terminal S and terminal 3 X1 TCM. See Special Tools
.
- If greater than the specified value, repair the open or high resistance in the affected circuit.
- Using the light blue probes J 35616-64B, test the ISS low signal circuit for less than 10 Ω between the jumper harness J 44152
terminal V and terminal 26 X1 TCM. See Special Tools
.
- If greater than the specified value, repair the open or high resistance in the affected circuit.
- Using a 5A fused jumper wire and the light blue probes J 35616-64B, test for greater than 10K Ω between the ISS high signal circuit terminal 3 X1 TCM and all other circuits of X1 TCM.
- If less than the specified value, the affected circuits are shorted together.
- Using a 5A fused jumper wire and the light blue probes J 35616-64B, test for greater than 10K Ω between the ISS low signal circuit terminal 26 X1 TCM and all other circuits of X1 TCM.
- If less than the specified value, the affected circuits are shorted together.
- If all circuits and connections test normal, replace the TCM.
IMPORTANT:
You must perform the Circuit/System Verification before proceeding with Circuit/System Testing.
IMPORTANT:
When test probing TCM harness terminals, it is imperative to use the proper test probe from the most current version of the J 35616 GM terminal test kit. Use of the brown J 35616-6 (1.00 mm) PCM probe in a 0.64 mm terminal will deform the terminal, resulting in intermittent open conditions. The correct probe for TCM harnesses is the light blue J 35616-64B probe.