LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2011 >> Camaro LS, Standard >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panel System Displays And Gauges >> Diagnostic Information and Procedures >> Driver Information Center Switch Malfunction >> Circuit/System Testing

Circuit/System Testing

Menu Switch Malfunction

  1. Ignition OFF, disconnect the harness connector at the S78 Turn Signal/Multi-Function Switch.
  2. Ignition ON, test for greater than 4.8 V between the signal circuit terminal 5 and ground.
    • If less than the specified range, test the signal circuit for an open/high resistance. If the circuit tests normal replace the P16 Instrument Cluster.
  3. If all circuits tests normal, replace the S78 Turn Signal/Multi-Function Switch.

UP, Down, or Set/Clear Switch Malfunction

  1. Ignition OFF, disconnect the S78 Turn Signal/Multi-Function Switch.
  2. While holding the S78 Turn Signal/Multi-Function Switch UP arrow in the UP position, test for 0.55-0.65k Ω between the signal circuit terminal 12 and the low reference terminal 6 at the switch.
    • If not within the specified range, replace the S78 Turn Signal/Multi-Function Switch.
  3. While holding the S78 Turn Signal/Multi-Function Switch DOWN arrow in the DOWN position, test for 1.5-1.7k Ω between the signal circuit terminal 12 and the low reference terminal 6 at the switch.
    • If not within the specified range, replace the S78 Turn Signal/Multi-Function Switch.
  4. While depressing the S78 Turn Signal/Multi-Function Switch Set/Clr button, test for 3.0-4.0k Ω between the signal circuit terminal 12 and the low reference terminal 6 at the switch.
    • If not within the specified range, replace the S78 Turn Signal/Multi-Function Switch.
  5. If all circuits tests normal, replace P16 Instrument Cluster.