Conditions for Setting the DTC
P0133, P0153, P015A, P015B, P015C or P015D
- The ECM detects that the HO2S 1 rich-to-lean or lean-to-rich average response time is greater than a calibrated value.
- The DTCs set within 60 s when the above condition is met.
P013A or P013C
The ECM detects that the accumulated mass air flow monitored during rich-to-lean transitions between 450-150 mV is greater than 75 grams.
P013B or P013D
The ECM detects that the accumulated mass air flow monitored during lean-to-rich transitions between 350-650 mV is greater than 75 grams.
P013E or P014A
The ECM detects that the HO2S voltage has not decreased below 450 mV within a calibrated value of accumulated air flow.
P013F or P014B
The ECM detects that the HO2S voltage has not increased above 350 mV within a calibrated value of accumulated air flow.
P2270 or P2272
The ECM does not detect a HO2S voltage greater than 800 mV before accumulated mass air flow exceeds a calibrated value.
P2271 or P2273
The ECM does not detect an HO2S voltage less than 100 mV before accumulated mass air flow exceeds a calibrated value.