Circuit/System Verification
WARNING: This page is about a different car, the 2016 GMC Acadia, 2016 Chevrolet Traverse, and 2016 Buick Enclave. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition ON.
- Verify the scan tool Mirror Select Switch parameter changes from Idle to Left and Right when cycling the Driver Door Lock/Window Switch.
- If the parameter does not change
Replace the Driver Door Lock/Window Switch.
- If the parameter changes
- If the parameter does not change
- Verify the scan tool Mirror Motor parameter changes from Idle to Up, Down, Right and Left when cycling the Driver Door Lock/Window Switch.
- If the parameter does not change
Replace the Driver Door Lock/Window Switch.
- If the parameter changes
- If the parameter does not change
- Verify the A9D Outside Rearview Mirror-Driver and A9P Outside Rearview Mirror-Passenger moves when commanding the Mirror Right/Left and Mirror Up/Down with a scan tool.
- If the A9D Outside Rearview Mirror-Driver or A9P Outside Rearview Mirror-Passenger does not move RIGHT or LEFT or UP or DOWN
Refer to Circuit/System Testing - Outside Mirror Movement Malfunction.
- If the A9D Outside Rearview Mirror-Driver and A9P Outside Rearview Mirror-Passenger moves RIGHT, LEFT, UP and DOWN
- If the A9D Outside Rearview Mirror-Driver or A9P Outside Rearview Mirror-Passenger does not move RIGHT or LEFT or UP or DOWN
- Verify the scan tool Mirror Vertical Position parameters are between 0.2-4.8 V and change when commanding the Mirror Vertical Movement Up/Down with a scan tool.
- If not between 0.2-4.8 V or does not change
Refer to Circuit/System Testing - Mirror Position Sensor Circuit Test.
- If between 0.2-4.8 V and changes
- If not between 0.2-4.8 V or does not change
- Verify the scan tool Mirror Horizontal Position parameters are between 0.2-4.8 V and change when commanding the Mirror Horizontal Movement Right/Left with a scan tool.
- If not between 0.2-4.8 V or does not change
Refer to Circuit/System Testing - Mirror Position Sensor Circuit Test.
- If between 0.2-4.8 V and changes
- If not between 0.2-4.8 V or does not change
- All OK.