Door Lock Switch Test

  1. Ignition OFF, disconnect the harness connector at the appropriate door lock/window switch.
  2. Test for infinite resistance between the signal terminals D and E and the ground terminal B with the switch in the open position.
    • If less than the specified value, replace the door lock switch.
  3. Test for less than 2 Ω between the signal terminal E and the ground terminal B with the switch in the lock position.
    • If greater than the specified range, replace the door lock/window switch.
  4. Test for less than 2 Ω between the signal terminal D and the ground terminal B with the switch in the unlock position.
    • If greater than the specified range, replace the door lock/window switch.

Door Latch

  1. Ignition OFF, disconnect the harness connector at the appropriate door latch.
  2. Install a 25 A fused jumper wire between one of the control terminals and 12 V. Momentarily install a jumper wire between the other control terminal and ground. Reverse the jumper wires at least two times, the door latch should perform the LOCK and UNLOCK functions.
    • If it does not perform as specified, replace the door latch.

Relay Test

  1. Ignition OFF, disconnect the appropriate relay.
  2. Test for 60-200 Ω between terminals 85 and 86.
    • If not within the specified range, replace the relay.
  3. Test for infinite resistance between the following terminals:
    • 30 and 86
    • 30 and 87
    • 30 and 85
    • 85 and 87
    • If less than the specified value, replace the relay.
  4. Test for less than 2 Ω between terminals 30 and 87A.
    • If greater than the specified range, replace the relay.
  5. Install a 3 A fused jumper wire between relay terminal 85 and 12 V. Install a jumper wire between relay terminal 86 and ground. Test for less than 2 Ω between terminals 30 and 87.