Air Speed - Auxiliary
There are 2 separate operator controls for the auxiliary HVAC system. There is the front auxiliary HVAC control assembly and the rear seat audio (RSA) control module. If the front auxiliary blower motor switch is in the AUX. position, then the system will only function with inputs to the front auxiliary HVAC control assembly. If the front auxiliary blower motor switch is in the OFF position, then the RSA control module does not respond to input. The auxiliary HVAC control module can not request A/C operation from the PCM. A rocker type switch on the RSA control module provides the operator the ability to select several blower speeds. The RSA control module uses a bar graph to indicate the selected blower speed. The auxiliary blower motor control processor supplies a 5-volt reference to the auxiliary HVAC control module on the auxiliary blower motor speed control circuit. The auxiliary HVAC control module pulls the 5-volt reference low towards ground to provide a blower motor speed signal. As the voltage decreases the blower speed increases. Power and ground are provided to the auxiliary blower motor control processor through the battery positive voltage and ground circuits.
Afterblow
Afterblow is a feature that dries the evaporator core by operating the blower motor after the engine is turned off. This reduces the amount of microbial growth that can create undesirable odors. The vehicle does not come equipped with the afterblow feature turned on. If the afterblow feature is required due to an odor concern, it must be turned on by the scan tool.
The following conditions must be met for afterblow to operate:
- The A/C compressor operated during the prior key cycle.
- The system voltage is at least 11 volts to start and 10 volts to continue to run.
- The ignition has been in the OFF position for at least 30 minutes.
Once the above conditions have been met the following sequence of events will occur:
- The blower will run for a range of 2 minutes 30 seconds to 4 minutes.
- The recirculation door moves to outside air position.
- The mode valve moves to the floor position.