LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2010 >> Traverse LT, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 468 (Engine Cooling System) >> Repair Instructions >> Cooling System Draining and Filling (Vac N Fill) >> Vac-N-Fill Procedure

Vac-N-Fill Procedure

WARNING: This page is about a different car, the 2016 GMC Acadia, 2016 Chevrolet Traverse, and 2016 Buick Enclave. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:

To prevent boiling of the coolant/water mixture in the vehicles cooling system, do not apply vacuum to a cooling system above 49°C (120°F). The tool will not operate properly when the coolant is boiling.

    Fig 1: Identifying Vac-N-Fill Cap
    GM1617435Courtesy of GENERAL MOTORS COMPANY
  1. Attach the Vac-N-Fill cap to the vehicles coolant fill port.
  2. Install the extension hose.
  3. Fig 2: Vacuum Gage Assembly
    GM1617436Courtesy of GENERAL MOTORS COMPANY
  4. Attach the vacuum gauge assembly to the Vac-N-Fill cap.
  5. Fig 3: Attaching Fill Hose To Barb Fitting On Vacuum Gage Assembly
    GM1617437Courtesy of GENERAL MOTORS COMPANY
  6. Attach the fill hose to the barb fitting on the vacuum gauge assembly.

    Ensure that the valve is closed.

  7. Fig 4: View Of Graduated Reservoir & Hose
    GM1617438Courtesy of GENERAL MOTORS COMPANY
    NOTE:

    Use a 50/50 mixture of DEX-COOL antifreeze and clean, drinkable water. Always use more coolant than necessary. This will eliminate air from being drawn into the cooling system.

  8. Pour the coolant mixture into the graduated reservoir.
  9. Place the fill hose in the graduated reservoir.
  10. NOTE:

    Prior to installing the vacuum tank onto the graduated reservoir, ensure that the drain valve located on the bottom of the tank is closed.

  11. Install the vacuum tank on the graduated reservoir with the fill hose routed through the cut-out area in the vacuum tank.
  12. Fig 5: View Of Venturi Assembly & Vacuum Tank
    GM1617439Courtesy of GENERAL MOTORS COMPANY
  13. Attach the venturi assembly to the vacuum tank.
  14. Fig 6: View Of Shop Air Hose & Venturi Assembly
    GM1617440Courtesy of GENERAL MOTORS COMPANY
  15. Attach a shop air hose to the venturi assembly.

    Ensure the valve on the venturi assembly is closed.

  16. Fig 7: Attaching Vacuum Hose To Vacuum Gauge Assembly & Vacuum Tank
    GM1617441Courtesy of GENERAL MOTORS COMPANY
  17. Attach the vacuum hose to the vacuum gauge assembly and the vacuum tank.
  18. Clamp off the overflow hose.
  19. Fig 8: Identifying Valve On Venturi Assembly
    GM1617442Courtesy of GENERAL MOTORS COMPANY
  20. Open the valve on the venturi assembly. The vacuum gauge will begin to rise and a hissing noise will be present.
  21. Fig 9: View Of Vacuum Gauge
    GM1617443Courtesy of GENERAL MOTORS COMPANY
  22. Continue to draw vacuum until the needle stops rising. This should be 610-660 mm Hg (24-26 in HG).

    Cooling hoses may start to collapse. This is normal due to vacuum draw.

  23. To aid in the fill process, position the graduated reservoir above the coolant fill port.
  24. Fig 10: Identifying Valve On Vacuum Gage Assembly
    GM1617446Courtesy of GENERAL MOTORS COMPANY
  25. Slowly open the valve on the vacuum gauge assembly. When the coolant reaches the top of the fill hose, close the valve. This will eliminate air from the fill hose.
  26. Close the valve on the venturi assembly.
  27. If there is a suspected leak in the cooling system, allow the system to stabilize under vacuum and monitor for vacuum loss.

    If vacuum loss is observed, refer to Loss of Coolant .

  28. Open the valve on the vacuum gauge assembly. The vacuum gauge will drop as coolant is drawn into the system.
  29. Fig 11: View Of Vacuum Gauge & Radiator
    GM1617448Courtesy of GENERAL MOTORS COMPANY
  30. Once the vacuum gauge reaches zero, close the valve on the vacuum gauge assembly and repeat steps 11-17.

    Remove the extension hose.

  31. Remove the J 42401  radiator cap and surge tank test adapter.
  32. Detach the Vac-N-Fill cap from the vehicles coolant fill port.
  33. Add coolant to the system as necessary.
  34. Inspect the concentration of the coolant mixture using J 26568  coolant and battery tester.
  35. NOTE:

    After filling the cooling system, the extraction hose can be used to remove excess coolant to achieve the proper coolant level.

  36. Detach the vacuum hose form the vacuum gauge assembly.
  37. Fig 12: Attaching Extraction Hose To Vacuum Hose
    GM1617450Courtesy of GENERAL MOTORS COMPANY
  38. Attach the extraction hose to the vacuum hose.
  39. Fig 13: Identifying Valve On Venturi Assembly
    GM1617453Courtesy of GENERAL MOTORS COMPANY
  40. Open the valve on the venturi assembly to start a vacuum draw.
  41. Fig 14: Using Extraction Hose To Draw Out Coolant
    GM1617456Courtesy of GENERAL MOTORS COMPANY
  42. Use the extraction hose to draw out coolant to the proper level.
  43. The vacuum tank has a drain valve on the bottom of the tank. Open the valve to drain coolant from the vacuum tank into a suitable container for disposal.