HUD Switch Malfunction
- Ignition OFF, disconnect the harness connector at the HUD switch assembly.
- Ignition OFF, test for less than 5 ohms between the low reference terminal 3 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance.
- Ignition ON, verify that all of the scan tool HUD Switch parameters are Inactive.
- If any is not Inactive, test the signal circuit terminal 6 for a short to ground. If the circuit tests normal, replace the HUD.
- Ignition ON, install a 3-amp fused jumper wire between the signal circuit terminal 6 and ground. Verify the scan tool HUD Switch parameters are Active.
- If any are not Active, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HUD.
- If all the circuits test normal, test or replace the HUD switch assembly.