Home >> Chevrolet >> 2010 >> Cobalt LS, 4D Sedan, Automatic >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transmission - 4T45-E - Description And Operation >> Description and Operation >> Automatic Transmission Hydraulic Diagrams >> Park - Engine Running (With Electronic Range Select Mode) >> Low and Reverse Band Applies >> 1-2 Shift Solenoid Valve

1-2 Shift Solenoid Valve

Energized by the PCM, the normally open 1-2 shift solenoid valve is On and blocks the 1-2 signal fluid from exhausting. The 1-2 signal fluid pressure acts on the 1-2 and the 3-4 shift valves.