DTC P0BFD (30): Motor Current Sensor Circuit Malfunction
- Before you troubleshoot, record all freeze data and any on-board snapshot, and review the general troubleshooting information (see GENERAL TROUBLESHOOTING INFORMATION ).
- If the DTC cannot be cleared, do the troubleshooting for DTC U1204(55).
- Turn the ignition switch to ON (II).
- Clear the DTC with the HDS (see DTC CLEAR ).
- Start the engine.
- Check for Pending or Confirmed DTCs with the HDS.
Is DTC P0BFD (30) indicated?
YES -go to step 5.
NO -Intermittent failure, the system is OK at this time.
- Check for Pending or Confirmed DTCs with the HDS.
Is DTC P0A5E (24), P0A5F (25), P0A61 (26), P0A62 (27), P0A64 (28), or P0A65 (29) indicated?
YES -Go to the indicated DTC's troubleshooting.
NO -Replace the phase motor current sensor (see MOTOR POWER INVERTER (MPI) MODULE REMOVAL/INSTALLATION ), then go to step 6.
- Start the engine.
- Check for Pending or Confirmed DTCs with the HDS.
Is DTC P0BFD (30) indicated?
YES -go to step 1.
NO -go to step 8.
- Monitor the OBD STATUS for DTC P0BFD (30) in the DTCs MENU with the HDS.
Does the screen indicate PASSED?
YES -Troubleshooting is complete. If any other Pending or Confirmed DTCs were indicated in step 7, go to the indicated DTC's troubleshooting.
NO -If the screen indicates FAILED, go to step 1. If the screen indicates NOT COMPLETED, keep the ignition switch ON (II) until a result comes on.