- Disconnect the CVT driven pulley pressure control solenoid valve connector (A) and the inhibitor solenoid connector (B).
- Remove the CVT driven pulley pressure control solenoid valve (C) (eight bolts), and remove the inhibitor solenoid (D) from the CVT driven pulley pressure control solenoid valve.
- Check that the filter (E) is in good condition, and replace it if it is clogged or damaged.
- Remove the two O-rings (F) from the inhibitor solenoid.
- Install the two O-rings on the inhibitor solenoid, then install the inhibitor solenoid on the CVT driven pulley pressure control solenoid valve.
- Install the CVT driven pulley pressure control solenoid valve (eight bolts) with the two dowel pins (G) and the separator plate (H) on the lower valve body (I).
- Connect the CVT driven pulley pressure control solenoid valve connector and the inhibitor solenoid connector.