Circuit/System Testing
WARNING: This page is about a different variant/trim than selected.
- Ignition OFF, disconnect the harness connector at the Q12 evaporative emission canister purge or the Q13 vent solenoid valve.
- Ignition ON, verify that a test lamp illuminates between the voltage supply circuit terminal and ground.
- If the test lamp does not illuminate, test the voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and the voltage supply circuit fuse is open, test or replace the evaporative emission canister purge solenoid valve.
- Connect a test lamp between the voltage supply circuit terminal and the control circuit terminal.
- Command the EVAP canister purge solenoid valve to 50 % with a scan tool, or the EVAP canister vent solenoid valve Venting and Not Venting. The test lamp should respond to the command.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the K20 ECM.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K20 ECM.
- If all circuits test normal, replace the appropriate solenoid valve.