- Slide the J 29569-1:
seal installer over the large spline of the turbine shaft.
- Coat the J 29569-1:
seal installer with transmission fluid.
- Use your fingers in order to guide the new Teflon™ seals over the J 29569-1:
seal installer and into the seal ring grooves on the turbine shaft.
- Remove the J 29569-1:
seal installer when the seals are in place.
NOTE:
In order to properly size the seals, keep the J 29569-2:
sizer in place for 5 minutes.
- Size the new Teflon™ seals. Use both halves of the J 29569-2:
sizer.
- Repeat steps 3.1 through 3.6 with J 29829-1:
seal installer and J 29829-2:
seal sizer on the small splined side of the turbine shaft.