#1 Checkball (Low/PRN)
Low fluid pressure seats the #1 checkball against the PRN fluid circuit and this pressure fills the Low/PRN fluid circuit. Low/PRN fluid is routed to the 1-2 shift valve.
Low fluid pressure seats the #1 checkball against the PRN fluid circuit and this pressure fills the Low/PRN fluid circuit. Low/PRN fluid is routed to the 1-2 shift valve.