Brake D Engaged
The line pressure which engaged clutch B is also supplied to clutch valve D.
In Reverse, solenoid 1 is switched ON and pressure control solenoid valve 4 is switched OFF. This causes the fluid to the reduction valve to flow to clutch valve D through solenoid valve 4.
The spool of clutch valve D is depressed, allowing fluid to pass to holding valve D.