LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2008 >> Optra LT, Automatic >> Repair and Diagnosis >> Transmission >> Hydraulic Diagrams >> Automatic Transaxle - ZF 4HP 16 - Service, Overhaul, Removal & Installation, Troubleshooting & Diagnosis >> Park or Neutral - Engine Running >> Line Pressure Control Valve >> Lubrication/Cooling

Line Pressure Control Valve: Lubrication/Cooling

The lubricating valve ensures that the converter is supplied with cooling oil first if the pump rate is low. The lubricating pressure valve also guarantees that the necessary amount of cooling and lubricating oil is available through the bypass duct.

The fluid which is supplied from the torque converter flows to the cooler through the lubrication valve.

Fig 1: Park or Neutral Schematic - Engine Running
GM1255896Courtesy of GENERAL MOTORS CORP.