Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the engine oil pressure (EOP) sensor.
- Ignition OFF, test for less than 1 ohm of resistance between the low reference circuit terminal 1 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the engine control module (ECM).
- Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 2 and ground.
- If greater than 5.2 volts, test the 5-volt reference circuit for a short to voltage. If the circuit tests normal, replace the ECM.
- Install a 3-amp fused jumper wire between the oil pressure sensor signal circuit terminal 3 and the low reference circuit terminal 1. Verify the scan tool Engine Oil Pressure Sensor parameter is less than 4.8 volts.
- If greater than 4.8 volts, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the EOP sensor.