Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the boost gage.
- Ignition OFF, test for less than 1 ohm of resistance between the boost gage ground circuit terminal D and ground.
- If greater than the specified range, test the circuit for a short to battery or open/high resistance.
- Ignition ON, verify a test lamp illuminates when connected between the boost gage B+ circuit terminal A and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition OFF, connect the harness connector at the boost gage.
- Ignition ON, verify that the boost gage performs a self test by the gage dial moving up to the 0 kPa (0 psi) marker.
- If the boost gage does not perform a self test, test the boost gage signal circuit terminal C for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, replace the boost gage.