LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2008 >> HHR SS, Standard >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panel System Displays & Gages >> Diagnostic Information and Procedures >> Boost Gage Malfunction >> Circuit/System Testing

Circuit/System Testing

  1. Ignition OFF, disconnect the harness connector at the boost gage.
  2. Ignition OFF, test for less than 1 ohm of resistance between the boost gage ground circuit terminal D and ground.
    • If greater than the specified range, test the circuit for a short to battery or open/high resistance.
  3. Ignition ON, verify a test lamp illuminates when connected between the boost gage B+ circuit terminal A and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
  4. Ignition OFF, connect the harness connector at the boost gage.
  5. Ignition ON, verify that the boost gage performs a self test by the gage dial moving up to the 0 kPa (0 psi) marker.
    • If the boost gage does not perform a self test, test the boost gage signal circuit terminal C for a short to ground or an open/high resistance. If the circuit tests normal, replace the ECM.
  6. If all circuits test normal, replace the boost gage.