The following fault table will help determine if a hydraulic circuit or an incorrect position of a valve train component affects the transmission operation.

Component Cause DTCs
1-2-3-4 and 3-5-R Clutch Housing Assembly 1-2-3-4 clutch backing plate retaining ring not seated, causing the piston to over-travel and cut 1-2-3-4 clutch piston seal P2723
Lower Control Valve Body Assembly Clutch select valve 3 stuck OFF - debris, sediment, binding or scored bore P2723
Upper Control Valve Body Assembly 1-2-3-4 Clutch regulator valve stuck - debris, sediment, binding or scored bore P2723
Fluid Pump Cover Assembly
  • Fluid pump cover pump damage or debris between torque converter housing causing pump slide damage
  • Fluid pump cover vanes and fluid pump rotor broken
P2723


The following fault table will help determine if a hydraulic circuit or an incorrect position of a valve train component affects the transmission operation.

Component Cause DTCs
1-2-3-4 and 3-5-R Clutch Housing Assembly 1-2-3-4 clutch backing plate retaining ring not seated, causing the piston to over-travel and cut the 1-2-3-4 clutch piston seal. P2723
Fluid Pump Cover Assembly
  • Fluid pump cover pump damage or debris between the torque converter housing causing pump slide damage.
  • Fluid pump cover vanes and fluid pump rotor broken
P2723
Lower Control Valve Body Assembly Clutch select valve stuck off - debris, sediment, binding, or scored bore P2723